Automatic vicat apparatus
Automatic vicat apparatus
Automatic vicat apparatus

63-L3000

The Automatic Vicat Apparatus 63-L3000 provides a completely automatic method for determining the initial and final setting time of cements or mortar pastes. Advanced electronics technologies provide superior performances and total flexibility. The Automatic Vicat Apparatus 63-L3000 is easy to operate and accurate in test results, can be an ideal helper in your experiments.

STANDARD

  • AASHTO T131
  • EN 196/3
  • ASTM C191
  • ASTM C187


Get Wholesale Price
Share:

The Automatic Vicat Apparatus 63-L3000 provides a completely automatic method for determining the initial and final setting time of cements or mortar pastes. Advanced electronics technologies provide superior performances and total flexibility. The Automatic Vicat Apparatus 63-L3000 is easy to operate and accurate in test results, can be an ideal helper in your experiments.

AUTOMATIC POSITION CALIBRATION
Fully automatic, one-key operation, automatic accurate position calibration;

POSITION STORAGE
After the position calibration is completed, it will be stored in memory, no need to repeat the calibration

AUTOMATIC TEST PROCESS
One-key operation, automatic penetration measurement, and
automatic lifting of components after completion;

INTELLIGENT TEST CONTROL
The penetration displacement value is displayed in real time, no need for frequent visual inspection during the test;

NO NEEDLE REPLACEMENT FOR INITIAL AND FINAL SETTING TEST
The initial and final setting test needles are shared, reducing costs and workload;

INTELLIGENT JUDGMENT OF RESULTS
Automatically judge the result data according to the requirements of the test specification, and prompt the operation;

DATA REPORT STORAGE
Test data is automatically made into charts and stored; equipped with RS485 communication and USB port.


TECHNICAL PARAMETERS

Time control
Time display resolution: 0.1S
Time control accuracy: ≤±0.1S
Displacement
Using high-precision LVDT displacement sensor, split structure, no friction when the needlefalls.
Range: 0-50mm
Displacement display resolution: 0.01mm
Relative displacement accuracy: 0.1mm
Data storage
200 sets
Slide assembly
300g ± 1g (including test rod/test needle), meets the requirements of the standard;
Communication port
RS485 data output port
USB data export interface
Accessories
Supporting glass plate
Φ10 mm Consistency plunger
Φ1.13 mm needle and Φ70/80mm conical mould to EN
(Φ1 mm needle and Φ60/70mm conical mould to ASTM/AASHTO optional)
Dimensions
390mm x 310mm ×575mm (length × width × height)
Power supply
220±10%VAC/50Hz; maximum 40W

-