TPDR-10/TPDR-16/TPDR-28
It is used to determine the resistance of concrete specimens to repeated cycles of freezing and thawing in the laboratory by rapid freezing and thawing in water method.
STANDARD
- ASTM C666
Get Wholesale Price
It is used to determine the resistance of concrete specimens to repeated cycles of freezing and thawing in the laboratory by rapid freezing and thawing in water method.
FEATURES
◎ The compressor, heating device and power control part are all imported parts with high quality and high performance.
◎ When running at full load, the temperature difference at each point in the freeze-thaw cabinet does not exceed ±2℃.
◎ Display data curves in real time and automatically store test data.
◎ It has an automatic recovery function when the test is accidentally interrupted.
◎ Easy installation, small footprint, low noise
TECHNICAL PARAMETERS
TPDR-10
Condenser cooling system: Air cooling
Specimen size: 100×100×400mm. The size of the specimen for temperature measurement is the same, a temperature measuring hole is required in the middle
Capacity: 10 pcs
Freeze-thaw cycle: 2.5~4 hours, the thawing time is not less than 1/4 freeze-thaw cycle
Center temperature control: 8~-17±2℃
Liquid temperature control: High temperature: 18~23℃; Low temperature: -23~-18℃
Diagonal temperature control: The temperature difference in the cabinet does not exceed 1°C
Secondary protection temperature control: 50℃~-30℃
Temperature recorder: Touch screen
Freeze-thaw cycle medium: -45℃ antifreeze
Freeze-thaw cycle medium filling volume: The liquid level is 10-15mm higher than the specimen
Refrigerator compressor: Fully enclosed 3HP
Heating power: 3kW
Power supply: 3N380V 50Hz
Dimensions: 1750×800×1100mm
TPDR-16
Condenser cooling system: Air cooling
Specimen size: 100×100×400mm. The size of the specimen for temperature measurement is the same, a temperature measuring hole is required in the middle
Capacity: 16 pcs
Freeze-thaw cycle: 2.5~4 hours, the thawing time is not less than 1/4 freeze-thaw cycle
Center temperature control: 5~-18±2℃
Liquid temperature control: High temperature: 18~23℃; Low temperature: -23~-18℃
Diagonal temperature control: The temperature difference in the cabinet does not exceed 2°C
Secondary protection temperature control: 50℃~-30℃
Temperature recorder: Touch screen
Freeze-thaw cycle medium: -45℃ antifreeze
Freeze-thaw cycle medium filling volume: The liquid level is 10-15mm higher than the specimen
Refrigerator compressor: Fully enclosed 5HP
Heating power: 4.5kW
Power supply: 3N380V 50Hz
Dimensions: 1760×900×1100mm
TPDR-28
Condenser cooling system: Air cooling
Specimen size: 100×100×400mm. The size of the specimen for temperature measurement is the same, a temperature measuring hole is required in the middle
Capacity: 28 pcs
Freeze-thaw cycle: 2.5~4 hours, the thawing time is not less than 1/4 freeze-thaw cycle
Center temperature control: 5~-18±2℃
Liquid temperature control: High temperature: 18~23℃; Low temperature: -23~-18℃
Diagonal temperature control: The temperature difference in the cabinet does not exceed 2°C
Secondary protection temperature control: 50℃~-30℃
Temperature recorder: Touch screen
Freeze-thaw cycle medium: -45℃ antifreeze
Freeze-thaw cycle medium filling volume: The liquid level is 10-15mm higher than the specimen
Refrigerator compressor: Fully enclosed 6HP
Heating power: 6kW
Power supply: 3N380V 50Hz
Dimensions: Chamber 1450*1100*1700mm; Air cooling system 1950*900*1250mm